C&K systems System 238 Instrukcja Instalacji Strona 7

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 6
SYSTEM 238 Installation Manual
7
PROGRAMMING the ALPHA KEYPAD
Keypad Message Programming
The Alpha keypad programming template is used to allow the in-
staller to program messages and zone descriptions into the Alpha
keypads. The template shown below should be used when pro-
gramming the keypad.
To activate the keypad programming mode, enter the [Installer's
Code] [*] [0] [1] [#]. Information may be entered into the key-
pad in the form of letters (upper and lower case), numbers (0 -
9), and 22 special symbols. All characters are displayed in the
order listed above, i.e. upper and lower case letters, numbers,
and special symbols. The [Space] character precedes the letter
A.
To enter a Message or Label, use the [2] key to scroll through the
characters until you reach the desired character. If you scroll past
the desired character, the [8] key may be used to scroll back-
wards.
When the desired character is displayed, press the [6] key to move
the cursor to the next character position. The [4] key moves the
cursor to the left. When all characters have been entered, press
the [#] key to write the message and move to the next message
position. Use the [0] key to move backward through the messages.
Ensure the Alpha keypad is wired to the SYSTEM 238 and power is
applied to the control panel. You can only access the programming
mode when the control panel is disarmed.
NOTE: Programming the Keypad is not the same as Keypad
Programming.
123
4
56
789
0
ALPHAII Programming Template
ALPHAPLUS Programming Template
12 3
65
4
78 9
0
NOTE: If you do not press any key for 5 minutes, the
keypad will automatically exit the programming
mode.
To Exit Keypad Programming
When you have finished programming, press [*] [#]. The keypad
will also exit the programming mode if you do not press any
key within a five minute period.
The Alpha Keypad
You can program the Alpha keypads for special messages, each
of the 8 zone labels, and the keypad address. Zone Labels
display during the walk-test and when the [#] key is pressed
during alarm memory or faults. The programmable Service
Message is displayed during AC failure, fuse failure, communica-
tion failure, or low battery. The Dealer Message displays when the
system is disarmed. The keypad address is initially displayed only
during system start up (see page 5, Keypad Addressing).
These messages can be programmed directly from the Alpha
keypad or remotely using the Commander II/Monitor II software
package. For more detailed information about remote program-
ming, refer to the Commander II/Monitor II Operating Manual.
The Scrolling order of the Alpha Plus messages is:
SERVICE MESSAGE
DEALER MESSAGE
SOFT ZONE IDENTIFIER (C)
HARDWIRED LOOP IDENTIFIERS
KEYPAD ADDRESS
Both the Alpha and the Alpha Plus use the same procedure to
program messages.
PROGRAMMING CONVERSIONS
Hexadecimal Value
Key Strokes
A
B
C
D
E
F
0
1
2
3
4
5
The last two Command Locations are CL 37 and CL A0. Pressing
the [#] key at these locations will advance you to CL 38 or CL A1,
respectively. Locations CL 38 and CL A1 are not used in the
SYSTEM 238. If you accidentally enter either of these locations,
press [*] [#] to exit programming, or enter the Command
Location number, followed by the [#] key, for the location you wish
to program.